Technical Information & support videos
FUNCTIONS
FILLING ¦ PRESSURE REDUCTION ¦ DISCONNECTION ¦ NON RETURN
| PERFORMANCE | |
|---|---|
| Pressure | |
| Maximum allowable (PN) | 10 bar |
| Adjustment range (Ps) | 1 – 3 bar +/- 10% |
| PS value set during testing | |
| DOMESTIC version (blue button) | 1.2 bar +/- 10% |
| COMMERCIAL version (green button) | 2.5 bar +/- 10% |
| Temperatures | |
| Operating temperature fluid inlet | 0°C (frost excluded) – 65°C |
| Operating temperature fluid outlet | 0°C (frost excluded) – 110°C |
| Compatible Fluids | |
| Water | |
| Glycolate solutions | Glycol at maximum 50% |
| Threads | |
| Pipe connections | Compression fittings for copper tube 15mm (EN 1254/2 with 1/2″ male on body ref ISO 228/1) |
| MATERIALS USED | |
|---|---|
| Brass parts in contact with water | Brass CW602N (CR) |
| Brass parts not in contact with water | Brass CW614N / CW617N |
| Plastic parts not in contact with water | PA, POM and PPE |
| Gaskets | EPOM Perox |
| Spring | Stainless steel |